• Make a Payment
  • My Account
1-800-468-8185 | Local: 541-923-4100 | Fax: 541-923-4141
  • Shopping Cart Shopping Cart
    0Shopping Cart
MHOxygen
  • Home
  • Products
    • Pulse-Demand™ Systems, Portable

      • O2D1 Kits and Systems
      • O2D2 Kits and Systems
      • Parts and Accessories, Pulse-demand
    • Constant Flow Systems, Portable

      • XCP Systems & Products for General Aviation
      • XCR Products for Sport Aviation
      • Flowmeters
      • Emergency Oxygen Systems
    • Built In

      • EDS Pulse Demand
      • Constant Flow
      • Regulators and Parts, Built In
      • Cylinder Mounting Options
      • Fill Ports
      • Gauges
      • Manifolds
    • Ground Support Equipment

      • Transfillers
      • Transfill Adapters
      • Transfill Adapters, Aircraft Fill
      • Transfill Adapters, Tank to Tank
      • Parts and Accessories, Ground Support
    • Cylinders & Accessories

      • Cylinders
      • Carry Cases
      • Cylinder Gauges
      • Cylinder Valves
      • Cylinder Mounting Options
    • Regulators, Pressure-reducing

      • CGA-540 (US)
      • DIN-477-9 (Int’l)
      • Inline Reducing Regulator (ILR)
      • SAE-4 Regulators
      • Two-stage Regulators
      • Emergency
      • Parts and Accessories, Regulator
    • Cannulas/Face Masks

      • Cannulas
      • E-Z Breathe Boom Cannula
      • Face Masks
      • Alps Face Mask
      • Parts and Accessories, Facemask
    • Fittings & Hardware

      • Clamps, O-Rings, Caps & Plugs
      • CPC (Quick Couplings)
      • Fittings High Pressure
      • Fittings Low Pressure
      • High Pressure Hoses
      • Tubing
    • Accessories, General

      • Accessories
      • Protective Gear
    • AITHRE

    • New Products

    • Specials

  • Support
    • Sales

      • Find a Dealer
      • Choosing an Oxygen System
    • Products

      • Manuals & Documentation
      • Product Notices
      • New Products & Product Updates
    • Service

      • Product Maintenance
      • Routine Service
      • RMA Request
    • Information

      • Shipping & Returns Policy
      • FAQs
      • FYI
      • Acronyms and Abbrev.
    • Tutorial Videos

      • EDS Pulse-demand™
      • EZ Breathe Cannula
      • Regulators
      • Tips and FAQs
      • Cylinder Transfilling
  • Videos
  • About
    • Contact Us
    • Good Press
    • Testimonials
    • Approvals and Certificates
    • Partner Links
    • Military
  • Cylinder Duration Chart
  • Click to open the search input field Click to open the search input field Search
  • Menu Menu
Aviation Oxygen Products
You are here: Home1 / Aviation Oxygen Products2 / Portable Pulse-Demand™ Systems3 / O2D2 Kits and Systems4 / O2D2 System (EDS, Regulator, Cylinder)
O2D2 System (EDS, Regulator, Cylinder)
O2D2 System (EDS, Regulator, Cylinder) - Image 2
O2D2 System (EDS, Regulator, Cylinder) - Image 3
O2D2 System (EDS, Regulator, Cylinder) - Image 4

O2D2 System (EDS, Regulator, Cylinder)

$1,350.00 – $3,650.00

Choose your complete oxygen system.

CGA-540 Standard North American

DIN-477 Euro Norm

Clear
SKU: 00EDS-2000
Category: O2D2 Kits and Systems Tags: Complete Oxygen System, EDS, O2D2, Pulse-demand
  • Description
  • PDF Documentation
  • Videos
  • Cylinder Size and Duration Chart
  • Common Add-ons
  • Specifications
  • FAQ

Our new Pulse Demand (2G) systems still incorporate all of the benefits of our legacy controllers but with many improvements. Like the series of the old VW Beetle, it’s the same, but better.

We started with the control switch: The EDS unit now incorporates a MIL-spec rugged, easy-to-grip, rotary control switch providing improved reliability, increased ease of function and visibility. This switch also has very positive position detentes for excellent tactile feedback, making it resistant to changes from casual rubbing or bumping.

While we were at it, we improved the manifold design to allow for better breathing response and effort tracking. This, combined with a new circuit board, as well as a new microcontroller, gives improved power-conserving operations with even less RFI emissions, better respire-metric tracking and dispensing of oxygen in finer resolution, resulting in smoother steps from altitude and breathing changes.

Other improvements include a dedicated bicolor-system battery status light allowing much easier monitoring and definitive indication of battery condition without being confused as a station operation. The original O2Dx units encoded the low-battery notification into the station lights. This status light also responds to each control switch change with a beep and green flash to confirm your actions. Also, the audio alerts and warnings are louder, more crisp and dynamic to human hearing in an effort to being heard over modest cabin noise. The O2D2 has a 600-ohm stereo external audio jack as well as a USB-compatible (5VDC) external power port.

More intuitive F-mode settings labeled as 1, 2, 3 & 4 for use with face masks or when more oxygen is required.

How Pulse Demand Works

The patented MH EDS (Electronic Delivery System) is a one- (O2D1-2G) or two-user (O2D2-2G) aviation oxygen delivery device. It is designed to deliver aviation oxygen in the most efficient, comfortable and convenient way possible. With its selectable settings, apnea alarm and small size, the MH EDS is the most portable and flexible electronic digital oxygen delivery system in the world. By providing a measured pulse of oxygen every time you breathe in, the MH EDS supplies the oxygen you need to stay alert and comfortable while flying. In contrast to constant-flow systems that waste oxygen by supplying more than your body can use, the MH EDS provides a short pulse of oxygen as you inhale, ensuring that your oxygen is used most efficiently. Efficient oxygen delivery means you can fly farther on a single oxygen refill or save space and weight with a smaller tank. It also makes it more feasible to enjoy the advantages of oxygen while flying below the altitudes where oxygen is mandated — that can mean fewer headaches, increased alertness, and feeling less exhausted when you reach your destination. Your actual oxygen usage will be determined by your breathing rate and physiological needs at altitude. The programmability of the MH EDS means that, unlike constant-flow oxygen systems, you can “set it and forget it.” By automatically detecting your pressure altitude, the MH EDS can be set to start providing oxygen immediately or at a specified altitude and will automatically adjust the oxygen flow as your altitude changes. When you’re flying, don’t you have more important things to do than adjust your oxygen flow during altitude changes?

EDS O2D2 Documentation

pdf

5IEDS-0020-00$-

Wiring the Audio Outputs of an O2D2 (Instructions)
Version: -
Size: 301.17 KB
pdf

5IEDS-0022-00

Maintenance Questions for O2D1 & O2D2 PULSE DEMAND™ Portable Systems
Version: 12/08/2021
Size: 426.88 KB
pdf

5MD20-0003-00$-1

EDS-2G User Manual (O2D1, O2D2)Digital Electronic Pulse-demand™ Aviation Oxygen Delivery System
Version: -1
Size: 5.97 MB
pdf

O2D2 Dimensions$-

O2D2 Form-Factor
Version: -
Size: 39.02 KB

EDS Technology Reference Documents

pdf

CAMI Altitude Chamber Profile$-

IP Test Protocol Waveform
Version: -
Size: 12.90 KB
pdf

CAMI Testing of Pulse Oxygen Systems

CAMI Performance Evaluation of Pulse Oxygen Designs Designated for General Aviation Use at Altitudes up to 25,000 Feet Above Sea Level
Size: 1.77 MB
pdf

EDS Firmware Updates (Dec 2010)

Pertinent Dealer Informationfor EDS O2D1 and O2D2 units
Size: 61.77 KB
pdf

EDS Oxygen Info

EDS Electronic ‘Pulse-Demand’Oxygen Delivery Systems Information
Size: 314.68 KB

EDS Accessories Documentation

pdf

5IEDS-0011-00 [00EDS-1078-00]

EDS Facemask Directions
Size: 2.37 MB
pdf

5IEDS-0014-00 [00EDS-1070-00]

Feed Tube to XCP Regulator, Directions
Size: 9.02 MB
pdf

5IEDS-0014-01 [00EDS-1070-01]

Feed Tube to XCP Regulator, Directions
Size: 244.69 KB
pdf

5IEDS-1070-03$A0 [00EDS-1070-03]

XCP to EDS Tubing Adapter
Version: A0
Size: 631.82 KB

EDS Operating Modes

Setting up an 02D1

Setting up your O2D2 System

Installing Batteries in an EDS

Introducing the EDS Pulse-demand Oxygen Systems

Mountain High Cylinder Duration Chart

Click here to open PDF in a new window.

(Some browser configurations may download the PDF. If no window opens, temporarily enable pop-ups or check your downloads folder.)


  • Cannula, E-Z Breathe-II Boom Cannula for EDS-Pulse Demand (One-Touch) Connector

    $99.00
  • E-Z Breathe QD, CPC Twist-Lock

    $17.50
  • Transfill Adapter, CGA-540 to AN-800

    $99.00
  • Transfill Adapter, DIN 477-9 to AN800

    $235.00

O2D2 DIM(md)

EDS-O2D2 Audio Wiring 5IEDS-0020-00(02D20-150-000$-0)[SCD](md)

O2D1-D2 Maint Questions 2012(md)

Related products

  • O2D1-DIN-477 w/G (New Euro)

    $995.00
  • O2D1-X-XCP-1P

    $950.00
  • O2D1-2G Kit

    $775.00
  • O2D2-2G with FPR 4-Port CGA-540 Regulator

    $1,425.00

Content Categories

  • EDS Videos (6)
  • EZ Breathe Videos (3)
  • FAQs (16)
  • FYI (4)
  • Good Press (8)
  • Jobs (2)
  • New Products & Product Updates (1)
  • Oxygen FAQs (7)
  • Product FAQs (9)
  • Product Notices (3)
  • Regulator Videos (2)
  • Testimonials (10)
  • Tips and FAQs (Videos) (5)
  • Transfilling Videos (3)
  • Tutorial Videos (17)

Product categories

  • Accessories, General (33)
  • AITHRE (8)
  • Built-In (71)
  • Cannulas/Face Masks (42)
  • Cylinders & Accessories (41)
  • Fittings & Hardware (204)
  • Ground Support Equipment (54)
  • New Products (14)
  • Portable Constant Flow Oxygen Systems (30)
  • Portable Pulse-Demand™ Systems (47)
    • Alps Face Mask (7)
    • O2D1 Kits and Systems (12)
    • O2D2 Kits and Systems (9)
    • Parts and Accessories, Pulse-demand (20)
  • Pressure Regulators (38)
  • Specials (2)

Pages

  • About Us
  • Acronyms and Abbrev.
  • Approvals and Certificates
  • Aviation Oxygen Products
  • Cart
  • Checkout
  • Choosing an Oxygen System
  • Contact Us
  • Cylinder Duration Chart
  • Find a Dealer
  • Frequently Asked Questions
  • Home
  • Jobs
  • Make a Payment
  • Manuals & Documentation
  • Military
  • My Account
  • Partner Links
  • Privacy Policy
  • Product Maintenance
  • RMA Request
  • Routine Service
  • Shipping & Returns Policy
Search Search
© Copyright 2025 - Mountain High E&S
  • Link to Facebook
  • Link to Youtube
  • Privacy Policy
Link to: Face Mask EDS Link to: Face Mask EDS Face Mask EDS Link to: EDS-4ip with IPR, Built-in Oxygen System Link to: EDS-4ip with IPR, Built-in Oxygen System EDS-4ip with IPR, Built-in Oxygen System
Scroll to top Scroll to top Scroll to top